Function Description Drawing of Medical Elevator & Observation Elevator
This document describes the functional design, structural features, operation modes, safety systems, and application requirements of Medical Elevators and Observation Elevators. It is used for project design, construction, installation, inspection, and maintenance reference.
Used for hospital patient transfer, stretcher, wheelchair, and medical equipment transportation
Stable operation, low noise, and high sanitation level
Supports emergency operation for rescue and disaster relief
Extra-large car space for stretcher and bed transportation
Two-way control panel for medical staff operation
Anti-bacterial, anti-corrosion, and easy-to-clean interior materials
Quiet and smooth running with reduced vibration
Self-testing and fault self-diagnosis system
Emergency intercom and remote monitoring interface
Overload protection and full-height light curtain
Door anti-pinch and fault automatic leveling
Emergency power supply and backup operation mode
Fire emergency return function
Rated load: 1000kg – 2500kg
Speed: 1.0m/s – 2.5m/s
Car height: ≥ 2400mm
Door width: ≥ 900mm – 1300mm
Installed in shopping malls, hotels, tourist attractions, and public buildings
Provides panoramic view while transporting passengers
Integrates transportation, landscape, and architectural decoration
Full glass or curved glass shaft and car wall
Stable and comfortable operation with low vibration
Energy-saving LED lighting and decorative ceiling
Stainless steel or aluminum alloy decorative structure
Weather-resistant and UV-protective glass design
Full-height safety light curtain and door protection
Speed limiter, buffer, and emergency brake
Fire protection and lightning protection system
Overload alarm and fault automatic alarm
Rated load: 630kg – 1600kg
Speed: 1.0m/s – 3.0m/s
Car style: panoramic, round, square, or curved
Installation: indoor shaft or outdoor exposed type
EN 81‑20 / EN 81‑50 (European safety standard)
GB 7588‑2003 (Chinese safety standard for elevators)
GB 10058 (General technical conditions for elevators)
Fire protection, energy saving, and environmental protection standards
Layout plan and installation dimensions
Car structure and internal layout
Control system and electrical schematic
Door system, safety device, and interface details
Installation space and civil engineering requirements
Editable drawing: DWG (AutoCAD)
BIM model: RFA (Revit)
Document: PDF
Unified layer, dimension, and annotation standard
DOWNLOAD